EI 90 fire rating is a 90-minute fire-resistance classification where a construction maintains integrity (E) and insulation (I) for an hour and a half. Integrity prevents flames/smoke passing through; insulation limits the temperature rise on the unexposed face, protecting people and adjacent materials for the full duration. Compared with EI 60, EI 90 imposes tighter limits on glass, profiles, seals, and junctions – and demands meticulous installation control.
At a glance
Note: EI’s insulation criterion keeps safe-side surfaces cooler, which also reduces radiant heat to safer levels for nearby occupants and finishes.
EI vs EW vs E - what’s the difference? | |||
|---|---|---|---|
| Property / Class | E (Integrity) | EW (Integrity + Radiation) | EI (Integrity + Insulation) |
| Stops flames/smoke passing | |||
| Limits radiant heat near the element | |||
| Limits temperature rise on unexposed face | |||
| Typical glazing make-up | Integrity fire glass | Radiation-control glass | Insulating fire glass (multi-laminate/intumescent) |
| Typical use cases | Low-proximity zones | Radiation control where EI not required | Close-proximity routes, protected spaces, sensitive areas |
1) Use a tested, documented assembly
Follow the exact combination of profiles/reinforcements, glazing, beads, seals, intumescent components, fixings, substrates and hardware stated in the classification report.
2) Glass type
Specify EI-rated insulating fire glass compatible with the system. These are typically multi-laminate/intumescent constructions with defined thickness, edge cover and weight; do not substitute EW or E glass.
3) Sizes & limits
Respect pane/leaf maximums, aspect ratios, visible edge cover, mullion/transom centres and profile spans. Oversizing requires formal EXAP/assessment.
4) Glazing details
5) Hardware & accessories
Only use listed hinges, locks, closers, panic hardware, drop seals and any electromagnetic hold-open devices referenced in evidence. For 90 minutes, verify closer power, bearing capacity and thermal protection of ironmongery.
6) Interfaces & substrates
Install into the tested substrate (e.g., concrete, lined stud). Match perimeter firestopping density/depth and record movement joints and deflection criteria.
7) Identification & maintenance
Apply ID labels, include DoP, installation and O&M manuals, and plan inspections (glass edges, seals, ironmongery). Longer-duration EI assemblies benefit from documented maintenance intervals.
EI 90 fire rating is achievable in aluminium systems when the tested build-up is followed precisely.
Scope: Usually fixed lights; openable EI-rated windows are uncommon and must be explicitly tested with the exact operating hardware and seals.
Glazing: Use the tested EI glass (type/thickness) and maintain edge cover and intumescent liners as specified.
Locations: Internal partitions to protected routes; external/boundary applications where the strategy requires 90-minute insulation.
Spec tips: Confirm pane maximums, permitted mullion/transom types, head/sole details; coordinate ventilation via AOVs or separate systems.
Leaf types: Single/double leaves, with/without overpanels/side-lights – each configuration must be covered by evidence.
Hardware: Only listed hinges, locks, closers, panic devices, drop seals. If hold-open is needed, use an automatic release linked to the fire alarm.
Additional performance: Smoke control (Sa/Sm) is separate to EI; include if required.
Spec tips: Check clearances, closer power, glazing bead type, ironmongery packers, and any kick/guard plates.
Layout: Keep to tested post spacing, deflection limits, and head-of-wall junctions. Unframed/butt-jointed glass is typically not permitted for EI unless specifically tested.
Interfaces: Use only approved fire stopping and tested substrates; document any movement joints.
People proximity: EI is preferred where occupants or combustibles may be close to the safe face for prolonged periods.
Spec tips: For door-integrated screens or full-height runs, ensure the combined assembly (door + side-light + overpanel) is within scope.
Build exactly to the documented configuration. If your intended size, hardware, glass or junction isn’t covered, obtain EXAP/assessment before proceeding.
Fire-rated aluminium doorset/screen – EI 90
Provide and install a factory-fabricated aluminium glazed doorset/screen classified to EN 13501-2: EI 90, tested to EN 1634-1/EN 1364-1 as applicable.
Construction, glazing, edge cover, seals, intumescent components, hardware and fixings shall match the tested/classified configuration.
Maximum sizes and aspect ratios shall not exceed those in the classification/assessment.
Install per the manufacturer’s instructions with approved perimeter firestopping.
Provide DoP, classification report, installation and maintenance manuals at handover.
The element maintains integrity and insulation for 90 minutes: no through-flames, and the safe-side temperature rise is limited (ΔTavg ≤ 140 °C; ΔTmax ≤ 180 °C).
Choose EI 90 where the fire strategy requires 90 minutes of insulation – e.g., higher-risk compartments, complex buildings, or where people/combustibles are near the glazing for extended periods.
No. Smoke control (Sa/Sm) is a separate classification and must be specified and evidenced independently.
Only if the combined assembly (door + screen + overpanel) is covered by evidence. Otherwise keep the elevation to EI or obtain an assessment.
Insulating fire glass (multi-laminate/intumescent) matched to the aluminium system, with specific thickness, weight and edge cover per the report.
Not without formal EXAP/assessment. Stick to tested sizes, hardware and construction to retain the EI 90 classification.
For more information on our fire rated windows and products please visit our Fire Rated Aluminium Windows
For more information on our fire rated doors and products please visit our Fire Rated Aluminium Doors
For more information on our fire rated partitions and products please visit our Fire Rated Glass Partitions