The system of fire-proof walls MB-78EI can be used to execute internal or external partitions with single and double doors and technical windows of fire-proof class EI30 to EI90, as provided under the following standard: PN-EN 13501-2+A1:2010. The system has been classified as non-fire propagating (NFP). It may also be applied for the purpose of building smoke-proof constructions.
The application of glazed fireproof barriers in building industry should be subject to the technical documentation of the building, designed in accordance with Technical Approval awarded by the ITB Institute [Building Research Institute], applicable standards and relevant regulations.
The MB-78EI system has gained widespread popularity among construction professionals due to its exceptional characteristics, optimised technology and constant technical development.
| MB-78EI Technical Parameters | |
|---|---|
| Air Permeability | Class 2, PN-EN 12207:2001 |
| Watertightness | Class 5A, PN-EN 12208:2001 |
| Fire Resistance | Classes EI 30, EI 60, EI 90 |
| Thermal Insulation | From 1.6 W(m²K) |
| Acoustic Insulation | Up to 41 dB |
| Technical Specification | |
|---|---|
| Depth of wall & door frame | 78mm |
| Depth of leaf | 78mm |
| Width of wall & door frame | 51mm / 72mm |
| Width of door leaf profiles | 72mm / 51mm |
| Glazing range | 8-65mm |
Or visit Aluprof MB-78EI to